Реле GN025DSR Crouzet
Технические характеристики: • Three-phase Motor Reversing solid-state relay
• Ratings from 25A and 50A per phase @ 48-530 VAC
• SCR output for heavy industrial loads
• DC control
• LED input status indicator
• UL508 Endurance Rating
• UL/CSA/ TUV Approved, CE Compliant to EN60950-1 PRODUCT SELECTION
Control Voltage 25A 50A
4-32 VDC GN025DSR GN050DSR
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description 25A 50A
Operating Voltage (47-63Hz) [Vrms] 48-530 48-530
Maximum Load Current [Arms] (2) 25 50
Transient Overvoltage [Vpk] 1100 1100
Maximum Off-State Leakage Current @ Rated Voltage [mArms] (3) 6 6
Minimum Load Current [Arms] 0.1 0.1
Maximum Surge Current 50/60 Hz (1 cycle) [Apk] 475/500 710/750
1 Second Surge Current 50/60 Hz [Apk] 100 150
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35 1.35
Maximum I²T for Fusing (50/60 Hz, 1/2 cycle) [A² sec] 1130/1030 2520/2320
Thermal Resistance Junction to Case (Rjc) [°C/W] 0.26 0.25
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (4) 500 500
HP Ratings at 120V / FLC 0.75 / 6.4A 1.5 / 12A
HP Ratings at 240V / FLC 1 / 4.2A 3 / 9.6A
HP Ratings at 480V / FLC 3 / 4.8A 7.5 / 11A
HP Ratings at 600V / FLC 5 / 6.1A 10 / 11A
INPUT SPECIFICATIONS (1)
Description Parameters
Control Voltage Range 4-32 VDC
Minimum Turn-On Voltage 4.0 VDC
Minimum Turn-Off Voltage 1.0 VDC
Minimum Input Current (for on-state) 23mA
Maximum Input Current 35mA
Input Resistance Current Regulated
Maximum Turn-On Time [msec] 150
Maximum Turn-Off Time [msec] 1/2 Cycle
Interlocking Time [msec] 100 GENERAL SPECIFICATIONS
Description Parameters
Input to Output Isolation 4000 Vrms
Input/ Output to Ground Isolation 2500 Vrms
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range -40 to 80°C
Ambient Storage Temperature Range -40 to 100 °C
Weight (typical) 13.1 oz (370g)
Housing Material UL 94V0 (self extinguishing
Input Terminal Screw Torque Range:[in lbs/Nm] 16.8/1.9
Output Terminal Screw Torque Range:[in lbs/Nm] 21.2/2.4
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) When mounted to the proper size heat sink (see derating curves)
3) Measured between 1/L1 and 2/T1 or 3/L2 and 4/T2
4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Коннект Маркет © ( www.ConMar.ru ) 2004-2021