Технические характеристики: Relay output
Mono-voltage
1 timed changeover and 1 instantaneous contact
Elapsed time can be saved mechanically in the event of a break in supply
Progress of cycle displayed
Housing 48 x 48 mm
Connection by screw-terminal base or 8-pin base. Specifications
Type Functions Relay outputs Delay Voltages
88 226 013 6 s 12 mm Multi-function 2 - 3 - 4 1 time changeover 5 A 1 instantaneous 12 min : - Max. timing 6 s - 60 s - 12 min- Dial graduation 0.1 s - 1 s - 12 s 24 V AC
Precision limit error ± 2 % (± 5 %/6 s)
Repetition accuracy ± 1.5 % (± 4 %/6 s)
Selection precision See "timing ranges" table for scale graduation
Reset time 0.20 s
Timed two-pole 1
Instantaneous single pole 1
Thermal rating 6,3 A
Rating (cos φ = 0.41) 104
operations 5 A - 230 V
Absorbed power-motor 3 VA cos φ 0,8
Voltage variation at maximum temperature of 55 oC
according to IEC 255 100
24 V +10 % - 42 V -15 %
48 V +10 % - 110 V -20 %
127 V 0 % - 220 V -20 %
240 V 0 %
Operator factor 100 %
Temperature limits use (°C) -10→+55
Temperature limits stored (°C) -20→70
Environmental protection Tropicalised to IEC 68-2-10
Vibration withstand on 3 axes (Veritas standard) 4 G - 55 Hz
Dielectric test voltage according to IEC 255 5 or VDE 0435 1000 V - Un ≤ 60 V
2000 V - Un > 60 V
Insulation according to standard VDE 0110 group C 380 V AC - 440 V DC
Protection Housing IP 40
Degree of terminal protection IP 10
Conformity to standards NFC 45250 - VDE 0110 - 0435 -
0660 or ICE 529
Connection : Screw/saddle
Terminal capacity Single-wire 1 or 2 leads Multi-wire 0,75 - 2,5 mm2
Terminal capacity Multi-wire 1 or 2 leads 0,5 - 1 mm 2
Mounting : Base mounting on 8-pin socket
Weight (g) 185