Технические характеристики: IP 67 protection against hydrocarbons, detergents
Double break switching
Double insulated or Atex flameproof casing
Choice of actuators Electrical characteristics
Rating nominal / 250 VAC (A) 6
Rating thermal / 250 VAC (A) 11
Mechanical characteristics
Maximum operating force (N) 3
Min. Release force (N) 0,6
Maximum total travel force (N) 4
Max. permitted overtravel force (N) 10
Maximum rest position (mm) A= 8,8
B= 9,8
Operating position depending on position of fixing holes
(mm)
A = 7.7±0.4
B = 8.7±0.4
Maximum differential travel (mm) 0,35 ±0,1
Min. overtravel (mm) 0,25
Ambient operating temperature (°C) 0 →+85
Mechanical life (operations) 107
Contact gap (mm) 0,3 x 2
Weight (g) 37
Fixations
Fixings - 4 holes (standard) A
Fixing - 2 holes B
Connections
Connection 4 flexible leads
0.75 mm2 length 0.50 m
Ø ext. 2.3 mm
Standard wire output S
Wire output on right D
Wire output on left G
Additional specifications
Components
Material
- Case : polyester UL94V0
- Contacts : silver
- Membrane : nitrile for 83 139 0 silicon for 83 139 1/2/5
Levers
- stainless steel
- Roller : polyamide